AM-902P Portable Anesthesia Machine

  • Detail
  • Parameters

Introduction                          

This isthe first manual, light-weight, compact, portable Anesthesia Machinespecifically

designedfor surgical locations where space or access is limited, such as:

• OfficeBased Anesthesia (OBA)

• Dentalanesthesia

•Missionary off-shore anesthesia

• Remotelocations in hospitals outside O.R.

•Disaster scenes and mass casualty incidents

•Front-line military hospitals

•Shipboard, aircraft

Anylocation where size, mobility and portability are important.

Technical Parameter

1. Workingmode: Manual

2.Patient scope: from Pediatric to Adult (3kgs over)

3. Tidalvolume: 20-1500ml

4.Working pressure: O2:0.3—0.4Mpa, N2O:0.3—0.4Mpa

5.Flowmeters: 2 tube 2 gas flowmeter; O2 range: 0.1-10L/min, N2O range:0.1-10L/min.

6. O2 andN2O linkage device (ORC system), FiO2 25%

7. APLvalve adjustment range: 0.5-6.0Kpa

8. O2Flush: 30-60L/min

Standard Configuration

- MainUnit

- OneVaporizer (choose one from below vaporizers)

Smallvaporizer: Halothane, Isoflurane, Enflurane

Bigvaporizer: Halothane, Isoflurane, Enflurane and Sevoflurane.

-Standard Accessories of breathing tubes for connecting and Mask etc.

-In-built Co2 absorber Canister with capacity of 2kg.

图片11.jpg图片12.jpg图片14.jpg图片15.jpg

Two Options

①Anesthesia Ventilator TH-1A

Special Feature

- IndependentAnesthesia Ventilator, with IPPV and Manual mode

- Withnecessary monitoring and alarm function,

to makesure the operation safety

- Gassupply: O2, or Air

- Withinternational connector, can be matched with

variousbrands of anesthesia machines

Specification

-Respiration mode: IPPV, SIMV, Manual

-Respiratory frequency: 1 to 65BPM

- Display:5.5´ SNT screen

- I:Eratio: 8:1~1:8

-Waveform: P-t, V-t

- MonitorParameters: Tidal volume; Minute Ventilation; Peak

- Tidalvolume: 50ml~1600ml

                 

Anesthesia VentilatorTH-1

Special Feature

- IndependentAnesthesia Ventilator, with IPPV and Manual mode

- Withnecessary monitoring and alarm function,

to makesure the operation safety

- Gassupply: O2, or Air

- Withinternational connector, can be matched with various

brands ofanesthesia machines图片16.png

Specification

- Controlmethod: Gas driving electronic controlled

- Breathfrequency: 1~90BPM

- Display:High light LED display

- I:Eratio: 4:1~1:6

-Respiration mode: IPPV, Manual

- MonitorParameters: Tidal volume; Minute Ventilation; Breath Frequency; Airway Pressure

- Tidalvolume: 50~1500ml图片17.png


Home
Customer service
Add to Enquiry List